diagnostic monitor

Syntax

diagnostic monitor {fan-tray  | line-module | management-module} [<SLOT-ID>]

no diagnostic monitor {fan-tray  | line-module | management-module} [<SLOT-ID>]

Description

Enables runtime diagnostics for all modules or for a specified module. This feature is enabled by default for all modules.

The no form of this command disables runtime diagnostics for all modules or for a specified module.

Command context

config

Parameters

fan-tray

Specifies the enabling of diagnostic monitoring specific to a fan tray.

line-module

Specifies the enabling of diagnostic monitoring specific to a line module.

management-module

Specifies the enabling of diagnostic monitoring specific to a management module.

<SLOT-ID>

Specifies the slot ID of a module. Format: member/slot.

Authority

Administrators or local user group members with execution rights for this command.

Usage

When no parameters are used in the command (diagnostic monitor or no diagnostic monitor), the command applies to all modules. This command impacts the diagnostics that run periodically. It does not affect on-demand diagnostics.

Example

Enabling runtime diagnostics for a specified module:

switch(config)# diagnostic monitor management-module 1/5