diagnostic monitor
Syntax
diagnostic monitor {fan-tray | line-module | management-module} [<SLOT-ID>]
no diagnostic monitor {fan-tray | line-module | management-module} [<SLOT-ID>]
Description
Enables runtime diagnostics for all modules or for a specified module. This feature is enabled by default for all modules.
The
no
form of this command disables runtime diagnostics for all modules or for a specified module.
Command context
config
Parameters
fan-tray
Specifies the enabling of diagnostic monitoring specific to a fan tray.
line-module
Specifies the enabling of diagnostic monitoring specific to a line module.
management-module
Specifies the enabling of diagnostic monitoring specific to a management module.
<SLOT-ID>
Specifies the slot ID of a module. Format: member/slot.
Authority
Administrators or local user group members with execution rights for this command.
Usage
When no parameters are used in the command (diagnostic monitor
or
no diagnostic monitor
), the command applies to all modules. This command impacts the diagnostics that run periodically. It does not affect on-demand diagnostics.
Example
Enabling runtime diagnostics for a specified module:
switch(config)# diagnostic monitor management-module 1/5