Power events

The following are the events related to power.

Event ID: 301

Message

PSU <name> changed state to <state>

Category

Power

Severity

Information

Description

Log the change in PSU status.

Event ID: 302 (Severity: Warning)

Message

PSUs inserted in the system are of <Type> types. This is <Support> configuration.

Category

Power

Severity

Warning

Description

Log the identification of mixed PSU types

Event ID: 303

Message

PSU <name> encountered a warning. Total warning count: <warnings>

Category

Power

Severity

Error

Description

Log the warnings encountered by the PSU

Event ID: 304

Message

PSU <name> faulted. Total fault count: <failures>

Category

Power

Severity

Error

Description

Log the failures encountered by the PSU

Event ID: 305 (Severity: Warning)

Message

PSU <name>: Internal communication <status>

Category

Power

Severity

Warning

Description

Log PSU internal communication failure

Event ID: 306 (Severity: Warning)

Message

PSU <name>: Fan-<fanidx> <status>

Category

Power

Severity

Warning

Description

Log PSU fan fault

Event ID: 307 (Severity: Warning)

Message

PSU <name>: <sensorid> sensor <status> threshold limit

Category

Power

Severity

Warning

Description

Log when PSU temperature sensor exceeded threshold

Event ID: 308

Message

PSU <name> has shutdown due to over temperature in <sensorid> sensor

Category

Power

Severity

Error

Description

Log when PSU temperature sensor triggered PSU shutdown

Event ID: 309 (Severity: Warning)

Message

PSU <name>: Output current <status> threshold limit

Category

Power

Severity

Warning

Description

Log when PSU output current exceeds threshold

Event ID: 310

Message

PSU <name> has shutdown due to output overcurrent

Category

Power

Severity

Error

Description

Log when PSU output current triggered PSU shutdown

Event ID: 311

Message

PSU <name> has shutdown due to output overvoltage

Category

Power

Severity

Error

Description

Log when PSU output voltage triggered PSU shutdown

Event ID: 312

Message

PSU Redundancy set to <redund>

Category

Power

Severity

Information

Description

Log a change in the PSU redundancy user configuration

Event ID: 313

Message

PSU Redundancy operating at <redund>

Category

Power

Severity

Information

Description

Log a change in the PSU redundancy operational state

Event ID: 314 (Severity: Warning)

Message

PSU <name> disabled: PSU airflow does not match system-airflow

Category

Power

Severity

Warning

Description

Log when PSU is disabled due to airflow direction mismatch

Event ID: 315

Message

PSU <name> disabled: PSU communication error

Category

Power

Severity

Error

Description

Log when PSU is disabled due to communication error

Event ID: 316 (Severity: Warning)

Message

<type> module <name> denied power due to insufficient power. Configured PoE power can be deconfigured to allow card to be granted power.

Category

Power

Severity

Warning

Description

There is insufficient power to power a card. Power can be removed from configured PoE PDs to be able to power the card.

Event ID: 317 (Severity: Warning)

Message

PSU <name> disabled: PSU inserted is not supported by the system

Category

Power

Severity

Warning

Description

Log when PSU is disabled due to an unsupported PSU

Event ID: 318 (Severity: Warning)

Message

Power over ethernet status has faulted

Category

Power

Severity

Warning

Description

Log 54V Power over ethernet status fault

Event ID: 319

Message

Power over ethernet status is good

Category

Power

Severity

Information

Description

Log 54V Power over ethernet status is good