Power events
The following are the events related to power.
Event ID: 301
Message |
PSU <name> changed state to <state> |
Category |
Power |
Severity |
Information |
Description |
Log the change in PSU status. |
Event ID: 302 (Severity: Warning)
Message |
PSUs inserted in the system are of <Type> types. This is <Support> configuration. |
Category |
Power |
Severity |
Warning |
Description |
Log the identification of mixed PSU types |
Event ID: 303
Message |
PSU <name> encountered a warning. Total warning count: <warnings> |
Category |
Power |
Severity |
Error |
Description |
Log the warnings encountered by the PSU |
Event ID: 304
Message |
PSU <name> faulted. Total fault count: <failures> |
Category |
Power |
Severity |
Error |
Description |
Log the failures encountered by the PSU |
Event ID: 305 (Severity: Warning)
Message |
PSU <name>: Internal communication <status> |
Category |
Power |
Severity |
Warning |
Description |
Log PSU internal communication failure |
Event ID: 306 (Severity: Warning)
Message |
PSU <name>: Fan-<fanidx> <status> |
Category |
Power |
Severity |
Warning |
Description |
Log PSU fan fault |
Event ID: 307 (Severity: Warning)
Message |
PSU <name>: <sensorid> sensor <status> threshold limit |
Category |
Power |
Severity |
Warning |
Description |
Log when PSU temperature sensor exceeded threshold |
Event ID: 308
Message |
PSU <name> has shutdown due to over temperature in <sensorid> sensor |
Category |
Power |
Severity |
Error |
Description |
Log when PSU temperature sensor triggered PSU shutdown |
Event ID: 309 (Severity: Warning)
Message |
PSU <name>: Output current <status> threshold limit |
Category |
Power |
Severity |
Warning |
Description |
Log when PSU output current exceeds threshold |
Event ID: 310
Message |
PSU <name> has shutdown due to output overcurrent |
Category |
Power |
Severity |
Error |
Description |
Log when PSU output current triggered PSU shutdown |
Event ID: 311
Message |
PSU <name> has shutdown due to output overvoltage |
Category |
Power |
Severity |
Error |
Description |
Log when PSU output voltage triggered PSU shutdown |
Event ID: 312
Message |
PSU Redundancy set to <redund> |
Category |
Power |
Severity |
Information |
Description |
Log a change in the PSU redundancy user configuration |
Event ID: 313
Message |
PSU Redundancy operating at <redund> |
Category |
Power |
Severity |
Information |
Description |
Log a change in the PSU redundancy operational state |
Event ID: 314 (Severity: Warning)
Message |
PSU <name> disabled: PSU airflow does not match system-airflow |
Category |
Power |
Severity |
Warning |
Description |
Log when PSU is disabled due to airflow direction mismatch |
Event ID: 315
Message |
PSU <name> disabled: PSU communication error |
Category |
Power |
Severity |
Error |
Description |
Log when PSU is disabled due to communication error |
Event ID: 316 (Severity: Warning)
Message |
<type> module <name> denied power due to insufficient power. Configured PoE power can be deconfigured to allow card to be granted power. |
Category |
Power |
Severity |
Warning |
Description |
There is insufficient power to power a card. Power can be removed from configured PoE PDs to be able to power the card. |
Event ID: 317 (Severity: Warning)
Message |
PSU <name> disabled: PSU inserted is not supported by the system |
Category |
Power |
Severity |
Warning |
Description |
Log when PSU is disabled due to an unsupported PSU |
Event ID: 318 (Severity: Warning)
Message |
Power over ethernet status has faulted |
Category |
Power |
Severity |
Warning |
Description |
Log 54V Power over ethernet status fault |
Event ID: 319
Message |
Power over ethernet status is good |
Category |
Power |
Severity |
Information |
Description |
Log 54V Power over ethernet status is good |