Fan events

The following are the events related to fan.

Event ID: 201

Message

There are <count> total fans in subsystem <subsystem>.

Category

Fan

Severity

Information

Description

Log the total number of fans in the subsystem

Event ID: 202

Message

Subsystem <subsystem> setting fan speed control register to <speedval>: <value>.

Category

Fan

Severity

Information

Description

Log the fan speed set

Event ID: 203

Message

Air flow direction: <value>.

Category

Fan

Severity

Information

Description

Log the air flow direction

Event ID: 204 (Severity: Warning)

Message

Fan tray <FT_Num> was removed.

Category

Fan

Severity

Warning

Description

Log event when a fan tray is removed from the chassis

Event ID: 205

Message

Fan tray <FT_Num> was inserted.

Category

Fan

Severity

Information

Description

Log event when a fan tray is inserted into the chassis

Event ID: 206

Message

Fan module <FMod_Num> in fan tray <FT_Num> was removed.

Category

Fan

Severity

Information

Description

Log event when a fan module is removed from a fan tray

Event ID: 207

Message

Fan module <FMod_Num> in fan tray <FT_Num> was inserted.

Category

Fan

Severity

Information

Description

Log event when a fan module is inserted into a fan tray

Event ID: 208

Message

Unsupported fan tray <FT_Num> detected. Please insert a standard fan tray.

Category

Fan

Severity

Error

Description

Log event when an unsupported fan tray is inserted

Event ID: 209

Message

Shutting down system now because <num_of_failure> <failure_type> <compare_mode> limit of <num_of_failure_limit>': yes

Category

Fan

Severity

Error

Description

Log error when system shutdown is initiated due to critical fan faults

Event ID: 211 (Severity: Warning)

Message

Shutting down system in <seconds> seconds because <num_of_failure> <failure_type> <compare_mode> limit of <num_of_failure_limit>

Category

Fan

Severity

Warning

Description

Log error when the number of failures exceed the allowable limit

Event ID: 212 (Severity: Warning)

Message

System shutdown timer is cancelled.': yes

Category

Fan

Severity

Warning

Description

Log event when the shutdown timer is cancelled

Event ID: 213

Message

<num_of_failure> <failure_type> in the system.': yes

Category

Fan

Severity

Error

Description

Log error when there are fan faults

Event ID: 214

Message

<function>: Fan fault in tray <tray_index>, module <fan_index>, reason: <reason>.': yes

Category

Fan

Severity

Error

Description

List out the faulty or missing fan names

Event ID: 215

Message

<FanName> fan is <FanStatus>.

Category

Fan

Severity

Information

Description

Log the fan status

Event ID: 216

Message

Status of fan <FanModuleIdx> in tray <FanTrayIdx> has changed from <OldStatus> to <NewStatus>.

Category

Fan

Severity

Information

Description

Log the change in fan status

Event ID: 217 (Severity: Warning)

Message

Operational fan count below minimum. <FanCount> fans operating, but <FanMinimum> are required.

Category

Fan

Severity

Warning

Description

Log when minimum number of fans are not present.

Event ID: 218

Message

Fan speed index for thermal zone <ZoneIdx> is <FanSpdIdxStatus>.

Category

Fan

Severity

Information

Description

Log when the fan speed index changes to and from the maximum for each thermal zone

Event ID: 219

Message

Fan tray <FT_Num> powered <Status>.

Category

Fan

Severity

Information

Description

Log event when a fan tray is powered on or off

Event ID: 220

Message

Fan tray <FT_Num> airflow is <FT_Dir>.

Category

Fan

Severity

Information

Description

Log event when a fan tray is inserted specifying its airflow direction

Event ID: 221 (Severity: Warning)

Message

<FT_air_curr> airflow fan tray <FT_Num> unsupported; this system requires <FT_air_req> airflow.

Category

Fan

Severity

Warning

Description

Log event when a fan tray airflow is not matching with system airflow

Event ID: 222

Message

<num_of_failure> <failure_type> <compare_mode> limit of <num_of_failure_limit>': yes

Category

Fan

Severity

Error

Description

Log error when number of faulty/supported fans does not meet the allowable limit

Event ID: 223 (Severity: Warning)

Message

Fan tray <FT_Num> FRU EPPROM is incorrectly programmed.

Category

Fan

Severity

Warning

Description

Log when fan tray SKU ID in FRU is mismatched

Event ID: 224 (Severity: Warning)

Message

<FT_air_curr> airflow fan tray <FT_Num> disabled; this system requires <FT_air_req> airflow.

Category

Fan

Severity

Warning

Description

Log event when a fan tray airflow is not matching with system airflow and is disabled

Event ID: 225 (Severity: Warning)

Message

fan tray <FT_Num> misconfigured; this fan tray has been <En_Dis>.

Category

Fan

Severity

Warning

Description

Log event when a misconfigured fan tray is enabled or disabled