Hardware Health Monitor events
The following are the events related to hardware health monitor.
Event ID: 3001
Message |
Diagnostic <test_name> failed with error code <error_code> on management module <slot>': yes |
Category |
Hardware Health Monitor |
Severity |
Error |
Description |
Event raised when hardware diagnostics detects error in management module |
Event ID: 3002
Message |
Diagnostic <test_name> failed with error code <error_code> on line card <slot>': yes |
Category |
Hardware Health Monitor |
Severity |
Error |
Description |
Event raised when hardware diagnostics detects error in line card |
Event ID: 3003
Message |
Diagnostic <test_name> failed with error code <error_code> on fabric card <slot>': yes |
Category |
Hardware Health Monitor |
Severity |
Error |
Description |
Event raised when hardware diagnostics detects error in fabric card |
Event ID: 3004
Message |
Diagnostic <test_name> failed with error code <error_code> on fan tray <slot>': yes |
Category |
Hardware Health Monitor |
Severity |
Error |
Description |
Event raised when hardware diagnostics detects error in fan tray |
Event ID: 3005
Message |
Diagnostic <test_name> failed with error code <error_code> on rear display card <slot>': yes |
Category |
Hardware Health Monitor |
Severity |
Error |
Description |
Event raised when hardware diagnostics detects error in rear display card |
Event ID: 3006
Message |
Diagnostic <test_name> failed with error code <error_code> for the system': yes |
Category |
Hardware Health Monitor |
Severity |
Error |
Description |
Event raised when hardware diagnostics detects error in the system |
Event ID: 3007 (Severity: Warning)
Message |
There are <origin> happening on <location>': yes |
Category |
Hardware Health Monitor |
Severity |
Warning |
Description |
Logs MCE BUS error |
Event ID: 3008 (Severity: Warning)
Message |
There are IO errors on <location> from <seg>:<bus>:<device>:<function>': yes |
Category |
Hardware Health Monitor |
Severity |
Warning |
Description |
Logs MCE IO error |
Event ID: 3009
Message |
There are unknown errors on <location> from <status>:<addr>:<misc>:<mcgstatus>:<cap>': yes |
Category |
Hardware Health Monitor |
Severity |
Information |
Description |
Logs MCE unknown error |
Event ID: 3010 (Severity: Warning)
Message |
CPUs <cpus> L<level> <type> cache error detected. CPUs <offlined> offlined': yes |
Category |
Hardware Health Monitor |
Severity |
Warning |
Description |
Logs CPU cache error |
Event ID: 3011 (Severity: Warning)
Message |
Socket <socket> correctable memory error count <cecount> exceeded threshold <threshold>': yes |
Category |
Hardware Health Monitor |
Severity |
Warning |
Description |
Log when socket correctable memory error count is exceeded threshold |
Event ID: 3012 (Severity: Warning)
Message |
Module <channel> correctable memory error count <cecount> exceeded threshold <threshold>': yes |
Category |
Hardware Health Monitor |
Severity |
Warning |
Description |
Log when module correctable memory error count is exceeded threshold |
Event ID: 3013 (Severity: Warning)
Message |
Page <page> correctable memory error count <cecount> exceeded threshold <threshold> and <offlined>': yes |
Category |
Hardware Health Monitor |
Severity |
Warning |
Description |
Log when page correctable memory error count is exceeded threshold |