In-System Programming events

The following are the events related to in-system programming.

Event ID: 7200

Message

Internal fatal error at <file>:<line>

Category

In-System Programming

Severity

Error

Description

ISP internal fatal error

Event ID: 7210

Message

Non-failsafe update needed for <devspec>. Please run the allow-unsafe-updates command

Category

In-System Programming

Severity

Error

Description

A non-failsafe device update is needed, but the allow-unsafe-updates command has not yet been run

Event ID: 7211

Message

Do not interrupt non-failsafe update for <devspec>

Category

In-System Programming

Severity

Error

Description

A non-failsafe device update is about to start, so do not interrupt it

Event ID: 7212

Message

Starting update for <devspec> from version <fromver> to version <tover>

Category

In-System Programming

Severity

Information

Description

A device update is about to start

Event ID: 7213

Message

Update successful for <devspec> from version <fromver> to version <tover>

Category

In-System Programming

Severity

Information

Description

A device update was successful or in some cases was successfully arranged to be performed later

Event ID: 7214 (Severity: Critical)

Message

Update failed for <devspec>

Category

In-System Programming

Severity

Critical

Description

A device update failed

Event ID: 7215

Message

Deferred update for <devspec> will be performed after an automatic module reset

Category

In-System Programming

Severity

Information

Description

A device update was postponed until after an automatic reset of its module

Event ID: 7216

Message

Approximately <time> minute(s) remaining to update <numdevs> device(s) on <modspec>

Category

In-System Programming

Severity

Information

Description

Indicates the approximate remaining update time for a module

Event ID: 7217

Message

Insufficient redundant power is available to update <devspec>

Category

In-System Programming

Severity

Information

Description

Unable to update non-redundant power supply

Event ID: 7218

Message

Programmable device updates are pending that require a power cycle. Wait for all fabric and line modules to be ready, then power the system off and back on again

Category

In-System Programming

Severity

Information

Description

ISP needs the chassis power-cycled manually when it cannot be done automatically

Event ID: 7219 (Severity: Critical)

Message

Failed to write-protect <devspec> (pass <pass>)

Category

In-System Programming

Severity

Critical

Description

Failed to write-protect a module or device