BFD Template
Use the BFD template to apply BFD configurations per segment to all appliances in the SD-WAN fabric, as follows:
-
Click the edit icon next to the segment for which you want to modify the configuration.
-
Configure the following fields:
Field Description Min Tx Interval Minimum transmit interval in milliseconds (ms). Specify a value from 300 to 5000. The default setting is 300. Min Rx Interval Minimum receive interval in milliseconds (ms). Specify a value from 300 to 5000. The default setting is 300. Detection Multiplier Detection time multiplier. In BFD, the detection time is the transmit interval multiplied by the detection multiplier. If BFD data is not received within the detection time, a failure occurs. Specify a value from 3 to 10. The default setting is 3. -
Click Update.